Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
06090 | TYCO ELECTRONICS CORPORATION DIV RAY |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
HUES | COLOR | BLACK |
STYL | STYLE DESIGNATOR | SHRINKABLE |
CQBC | MINIMUM TENSILE STRENGTH | 2500 POUNDS PER SQUARE INCH |
ABHP | OVERALL LENGTH | 4.000 FEET NOMINAL |
FLEX | FLEXIBILITY | FLEXIBLE |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 1300.0 |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
MATL | MATERIAL | PLASTIC, POLYOLEFIN, RT-301, RAYCHEM CORP |
ADZC | ENVIRONMENTAL PROTECTION | MILDEW RESISTANT AND PETROLEUM RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT AND FLAME RESISTANT AND HYDRAULIC FLUID |
AFZN | RECOVERED WALL THICKNESS | 0.020 INCHES NOMINAL |
AFZM | RECOVERED INSIDE DIAMETER | 0.093 INCHES MAXIMUM |
AFZL | EXPANDED INSIDE DIAMETER | 0.187 INCHES MINIMUM |
ABJH | TEMP RATING | -55.0 DEG CELSIUS AND 175.0 DEG CELSIUS |